Skip to main content
Erschienen in: Fire Technology 1/2024

31.12.2023

Numerical Analysis for Behavior of Stainless-Steel Web Cleat Connections at Elevated Temperatures

verfasst von: Zhengyi Kong, Cuiqiang Shi, Bo Yang, George Vasdravellis, Seung-Eock Kim, Quang-Viet Vu

Erschienen in: Fire Technology | Ausgabe 1/2024

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Stainless steel offers the advantages of excellent mechanical properties and exceptional corrosion resistance, making it a commonly used material in engineering. However, occasional fire incidents in engineering pose a significant risk to the safety of stainless steel structures. Among the critical components, the stainless steel beam-to-column connections play a crucial role in maintaining the structural integrity of stainless steel frames. Neglecting the influence of temperature on these connections could lead to catastrophic accidents in engineering. Thus, the main purpose of this study is to observe the behavior of stainless steel web cleat connections (SSWCC) at elevated temperatures. A finite element method, which has been validated through prior experiments, is developed to predict the behavior of the SSWCC under shear at elevated temperatures. The influences of various parameters, such as the number of bolts, angle thickness, gage distance, and temperature, on the moment-rotation behavior of the SSWCC are discussed. Temperature significantly affects both the initial rigidity and moment capacity of the SSWCC. Specifically, the initial rigidity and moment capacity of specimens decrease by 75% and 85%, respectively, when the temperature increases from 300°C to 900°C. Previous models do not precisely match the moment-rotation curves of the SSWCC at elevated temperatures; consequently, more precise model for the initial rigidity of the SSWCC at elevated temperatures are proposed in this work. Additionally, a previous model based on the yield line method is improved to represent the moment capacity of a SSWCC more accurately.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Jiang B, Yin Z, Zhang J, Fan C, Li Y (2021) Effect of rotational restraint conditions on performance of steel columns in fire. Eng Struct 238:112237CrossRef Jiang B, Yin Z, Zhang J, Fan C, Li Y (2021) Effect of rotational restraint conditions on performance of steel columns in fire. Eng Struct 238:112237CrossRef
2.
Zurück zum Zitat Elsawaf SA, Hassan MM (2018) Behaviour of structural sub-assemblies of steel beams with openings in fire conditions. J Constr Steel Res 148:627–638CrossRef Elsawaf SA, Hassan MM (2018) Behaviour of structural sub-assemblies of steel beams with openings in fire conditions. J Constr Steel Res 148:627–638CrossRef
3.
Zurück zum Zitat Yang J, Wang W, Shi Y, Xu L (2020) Experimental study on fire resistance of cold-formed steel built-up box columns. Thin-Walled Struct 147:106564CrossRef Yang J, Wang W, Shi Y, Xu L (2020) Experimental study on fire resistance of cold-formed steel built-up box columns. Thin-Walled Struct 147:106564CrossRef
4.
Zurück zum Zitat Pires T, Silva J, Santos M, Costa LM (2020) Fire resistance of built-up cold-formed steel columns. J Constr Steel Res 177:106456CrossRef Pires T, Silva J, Santos M, Costa LM (2020) Fire resistance of built-up cold-formed steel columns. J Constr Steel Res 177:106456CrossRef
5.
Zurück zum Zitat Ramesh S, Choe L, Zhang C (2020) Experimental investigation of structural steel beams subjected to localized fire. Eng Struct 218:110844CrossRef Ramesh S, Choe L, Zhang C (2020) Experimental investigation of structural steel beams subjected to localized fire. Eng Struct 218:110844CrossRef
6.
Zurück zum Zitat Wu Y, Fan S, He B, Li C, Zhou H (2021) Experimental study and numerical simulation analysis of the fire resistance of high-strength steel columns with rectangular sections under axial compression. Fire Saf J 121:103226CrossRef Wu Y, Fan S, He B, Li C, Zhou H (2021) Experimental study and numerical simulation analysis of the fire resistance of high-strength steel columns with rectangular sections under axial compression. Fire Saf J 121:103226CrossRef
7.
Zurück zum Zitat Wu Y, Fan S, He B, Liu M, Zhou H (2020) Research on the fre resistance design of high-strength steel hollow columns under axial compression. Eng Struct 234:111943CrossRef Wu Y, Fan S, He B, Liu M, Zhou H (2020) Research on the fre resistance design of high-strength steel hollow columns under axial compression. Eng Struct 234:111943CrossRef
8.
Zurück zum Zitat Gao Y, Yu H, Shi G (2013) Resistance of flush endplate connections under tension and shear in fire - ScienceDirect. J Constr Steel Res 86(1):195–205CrossRef Gao Y, Yu H, Shi G (2013) Resistance of flush endplate connections under tension and shear in fire - ScienceDirect. J Constr Steel Res 86(1):195–205CrossRef
9.
Zurück zum Zitat Qiang X, Jiang X, Bijlaard F, Kolstein H, Luo Y (2014) Post-fire behaviour of high strength steel endplate connections — Part 1: Experimental study. J Constr Steel Res 108(may):82–93 Qiang X, Jiang X, Bijlaard F, Kolstein H, Luo Y (2014) Post-fire behaviour of high strength steel endplate connections — Part 1: Experimental study. J Constr Steel Res 108(may):82–93
10.
Zurück zum Zitat Qiang X, Bijlaard F, Kolstein H, Jiang X (2014) Behaviour of beam-to-column high strength steel endplate connections under fire conditions – Part 1: experimental study. Eng Struct 64:23–38CrossRef Qiang X, Bijlaard F, Kolstein H, Jiang X (2014) Behaviour of beam-to-column high strength steel endplate connections under fire conditions – Part 1: experimental study. Eng Struct 64:23–38CrossRef
11.
Zurück zum Zitat Tran VL (2020) Moment-rotation-temperature model of semi-rigid cruciform flush endplate connection in fire. Fire Saf J 114:102992CrossRef Tran VL (2020) Moment-rotation-temperature model of semi-rigid cruciform flush endplate connection in fire. Fire Saf J 114:102992CrossRef
12.
Zurück zum Zitat Kodur V, Dwaikat M (2009) Response of steel beam–columns exposed to fire. Eng Struct 31(2):369–379CrossRef Kodur V, Dwaikat M (2009) Response of steel beam–columns exposed to fire. Eng Struct 31(2):369–379CrossRef
13.
Zurück zum Zitat Choe L, Varma AH, Agarwal A, Surovek A (2010) Experimental investigation of steel beam-columns under fire loading. Proceedings of the 2010 structures congress, American Society of Civil Engineers, Orlando, FL, USA Choe L, Varma AH, Agarwal A, Surovek A (2010) Experimental investigation of steel beam-columns under fire loading. Proceedings of the 2010 structures congress, American Society of Civil Engineers, Orlando, FL, USA
14.
Zurück zum Zitat Dwaikat MMS, Kodur VKR, Quiel SE, Garlock MEM (2011) Experimental behavior of steel beam-columns subjected to fire-induced thermal gradients. J Constr Steel Res 67(1):30–38CrossRef Dwaikat MMS, Kodur VKR, Quiel SE, Garlock MEM (2011) Experimental behavior of steel beam-columns subjected to fire-induced thermal gradients. J Constr Steel Res 67(1):30–38CrossRef
15.
Zurück zum Zitat Mao CJ, Chiou YJ, Hsiao PA, Ho MC (2009) Fire response of steel semi-rigid beam–column moment connections. J Constr Steel Res 65(6):1290–1303CrossRef Mao CJ, Chiou YJ, Hsiao PA, Ho MC (2009) Fire response of steel semi-rigid beam–column moment connections. J Constr Steel Res 65(6):1290–1303CrossRef
16.
Zurück zum Zitat European Committee for Standardization (2009) BS EN 1993–1–2 Eurocode 3: Design of steel structures, Part 1–2, General rules – Structural fire design, European Committee for Standardization, European Committee for Standardization European Committee for Standardization (2009) BS EN 1993–1–2 Eurocode 3: Design of steel structures, Part 1–2, General rules – Structural fire design, European Committee for Standardization, European Committee for Standardization
17.
Zurück zum Zitat Qiao X, Wang Y, Jia L (2017) The application and research of the stainless steel form of connections with welded flange and bolted webs. Ind Constr 17:154–162 Qiao X, Wang Y, Jia L (2017) The application and research of the stainless steel form of connections with welded flange and bolted webs. Ind Constr 17:154–162
18.
Zurück zum Zitat Jian K, Zhao O (2022) Experimental and numerical studies of stainless steel angle-to-plate connections. Thin-Walled Struct 173:109026CrossRef Jian K, Zhao O (2022) Experimental and numerical studies of stainless steel angle-to-plate connections. Thin-Walled Struct 173:109026CrossRef
19.
Zurück zum Zitat Sarfarazi S, Shamass R, Mascolo I, Della Corte G, Guarracino F (2023) Some Considerations on the behaviour of bolted stainless-steel beam-to-column connections: a simplified analytical approach. Metals 13(4):753CrossRef Sarfarazi S, Shamass R, Mascolo I, Della Corte G, Guarracino F (2023) Some Considerations on the behaviour of bolted stainless-steel beam-to-column connections: a simplified analytical approach. Metals 13(4):753CrossRef
20.
Zurück zum Zitat Xing Z, Zhao O, Kucukler M, Gardner L (2021) Fire testing of austenitic stainless steel I-section beam–columns. Thin-Walled Struct 164(46):107916CrossRef Xing Z, Zhao O, Kucukler M, Gardner L (2021) Fire testing of austenitic stainless steel I-section beam–columns. Thin-Walled Struct 164(46):107916CrossRef
21.
Zurück zum Zitat Xing Z, Zhou O, Kucukler M, Gardner L (2021) Testing of stainless steel I-section columns in fire. Eng Struct 227:111320CrossRef Xing Z, Zhou O, Kucukler M, Gardner L (2021) Testing of stainless steel I-section columns in fire. Eng Struct 227:111320CrossRef
22.
Zurück zum Zitat Kucukler M, Xing Z, Gardner L (2020) Behaviour and design of stainless steel I-section columns in fire. J Constr Steel Res 165:105890CrossRef Kucukler M, Xing Z, Gardner L (2020) Behaviour and design of stainless steel I-section columns in fire. J Constr Steel Res 165:105890CrossRef
23.
Zurück zum Zitat Jiang K, Zhao O (2023) Ferritic stainless steel thin sheet bolted connections failing by bearing–curling interaction: Testing, modelling and design. Eng Struct 283:115919CrossRef Jiang K, Zhao O (2023) Ferritic stainless steel thin sheet bolted connections failing by bearing–curling interaction: Testing, modelling and design. Eng Struct 283:115919CrossRef
24.
Zurück zum Zitat Jiang K, Zha O (2022) Experimental and numerical studies of stainless steel angle-to-plate connections. Thin-Walled Struct 173:109026CrossRef Jiang K, Zha O (2022) Experimental and numerical studies of stainless steel angle-to-plate connections. Thin-Walled Struct 173:109026CrossRef
25.
Zurück zum Zitat Ding R, Fan S, Chen G, Li C, Du E, Liu C (2019) Fire resistance design method for restrained stainless steel H-section columns under axial compression. Fire Saf J 108(102837):1-102837.20 Ding R, Fan S, Chen G, Li C, Du E, Liu C (2019) Fire resistance design method for restrained stainless steel H-section columns under axial compression. Fire Saf J 108(102837):1-102837.20
26.
Zurück zum Zitat Liu M, Fan S, Ding R, Chen G, Du E, Wang K (2019) Experimental investigation on the fire resistance of restrained stainless steel H-section columns. J Constr Steel Res 163:105770CrossRef Liu M, Fan S, Ding R, Chen G, Du E, Wang K (2019) Experimental investigation on the fire resistance of restrained stainless steel H-section columns. J Constr Steel Res 163:105770CrossRef
27.
Zurück zum Zitat Zhao J, Wang Z, Peng Y, Liu X, Dong J (2022) Experimental and numerical study on reduction coefficient of the shear capacity of austenitic long stainless-steel bolted connections[J]. Eng Struct 267:114610CrossRef Zhao J, Wang Z, Peng Y, Liu X, Dong J (2022) Experimental and numerical study on reduction coefficient of the shear capacity of austenitic long stainless-steel bolted connections[J]. Eng Struct 267:114610CrossRef
28.
Zurück zum Zitat Cai Y, Young B (2018) Structural behaviour of cold-formed stainless steel bolted connections at post-fire condition. J Constr Steel Res 152:312–321CrossRef Cai Y, Young B (2018) Structural behaviour of cold-formed stainless steel bolted connections at post-fire condition. J Constr Steel Res 152:312–321CrossRef
29.
Zurück zum Zitat Cai Y, Young B (2015) High temperature tests of cold-formed stainless steel double shear bolted connections. J Constr Steel Res 104:49–63CrossRef Cai Y, Young B (2015) High temperature tests of cold-formed stainless steel double shear bolted connections. J Constr Steel Res 104:49–63CrossRef
30.
Zurück zum Zitat Fan S, Wu Q, Ding R, Jia L, Zhou H (2021) Experimental and numerical research on fire resistance of stainless steel tubular X-joints. J Constr Steel Res 182(1):106654CrossRef Fan S, Wu Q, Ding R, Jia L, Zhou H (2021) Experimental and numerical research on fire resistance of stainless steel tubular X-joints. J Constr Steel Res 182(1):106654CrossRef
31.
Zurück zum Zitat Kong Z, Jin Y, Yang F, Vu Q-V, Truong V-H, Yu B, Kim S-E (2021) Numerical simulation for structural behaviour of stainless steel web cleat connections. J Constr Steel Res 183:106706CrossRef Kong Z, Jin Y, Yang F, Vu Q-V, Truong V-H, Yu B, Kim S-E (2021) Numerical simulation for structural behaviour of stainless steel web cleat connections. J Constr Steel Res 183:106706CrossRef
32.
Zurück zum Zitat Rahnavard R, Thomas RJ (2018) Numerical evaluation of the effects of fire on steel connections; Part 1: Simulation techniques, case studies in thermal. Engineering 12:445–453 Rahnavard R, Thomas RJ (2018) Numerical evaluation of the effects of fire on steel connections; Part 1: Simulation techniques, case studies in thermal. Engineering 12:445–453
33.
Zurück zum Zitat Qiang X, Bijlaard FS, Kolstein H, Jiang X (2014) Behaviour of beam-to-column high strength steel endplate connections under fire conditions–Part 2: numerical study. Eng Struct 64:39–51CrossRef Qiang X, Bijlaard FS, Kolstein H, Jiang X (2014) Behaviour of beam-to-column high strength steel endplate connections under fire conditions–Part 2: numerical study. Eng Struct 64:39–51CrossRef
34.
Zurück zum Zitat Qiang X, Bijlaard F, Kolstein H, Xu J (2014) Post-fire behaviour of high strength steel endplate connections — Part 2: numerical study. Eng Struct 64:23–38CrossRef Qiang X, Bijlaard F, Kolstein H, Xu J (2014) Post-fire behaviour of high strength steel endplate connections — Part 2: numerical study. Eng Struct 64:23–38CrossRef
35.
Zurück zum Zitat Li GQ, Chen LZ, Li JT, Lou GB (2012) Modeling of end-plate bolted composite connection in fire considering axial force effects. J Constr Steel Res 76:133–143CrossRef Li GQ, Chen LZ, Li JT, Lou GB (2012) Modeling of end-plate bolted composite connection in fire considering axial force effects. J Constr Steel Res 76:133–143CrossRef
36.
Zurück zum Zitat Al-Jabri KS, Seibi A, Karrech A (2006) Modelling of unstiffened flush end-plate bolted connections in fire. J Constr Steel Res 62(1/2):151–159CrossRef Al-Jabri KS, Seibi A, Karrech A (2006) Modelling of unstiffened flush end-plate bolted connections in fire. J Constr Steel Res 62(1/2):151–159CrossRef
37.
Zurück zum Zitat Lin S, Huang Z, Fan M (2014) Modelling partial end-plate connections under fire conditions. J Constr Steel Res 99:18–34CrossRef Lin S, Huang Z, Fan M (2014) Modelling partial end-plate connections under fire conditions. J Constr Steel Res 99:18–34CrossRef
38.
Zurück zum Zitat Qian ZH, Tan KH, Burgess IW (2009) Numerical and analytical investigations of steel beam-to-column joints at elevated temperatures. J Constr Steel Res 65(5):1043–1054CrossRef Qian ZH, Tan KH, Burgess IW (2009) Numerical and analytical investigations of steel beam-to-column joints at elevated temperatures. J Constr Steel Res 65(5):1043–1054CrossRef
39.
Zurück zum Zitat Kong Z, Hong S, Vu Q-V, Cao X, Kim S-E, Yu B (2019) New equations predicting initial stiffness and ultimate moment of flush end-plate connections. J Constr Steel Res 175:1–12 Kong Z, Hong S, Vu Q-V, Cao X, Kim S-E, Yu B (2019) New equations predicting initial stiffness and ultimate moment of flush end-plate connections. J Constr Steel Res 175:1–12
40.
Zurück zum Zitat Bu Y, Wang Y, Zhao Y (2019) Study of stainless steel bolted extended end-plate joints under seismic loading. Thin-Walled Struct 144:1–12CrossRef Bu Y, Wang Y, Zhao Y (2019) Study of stainless steel bolted extended end-plate joints under seismic loading. Thin-Walled Struct 144:1–12CrossRef
41.
Zurück zum Zitat Elflah M, Theofanous M, Dirar S (2019) Behaviour of stainless steel beam-to-column joints-part 2: numerical modelling and parametric study. J Constr Steel Res 152:194–212CrossRef Elflah M, Theofanous M, Dirar S (2019) Behaviour of stainless steel beam-to-column joints-part 2: numerical modelling and parametric study. J Constr Steel Res 152:194–212CrossRef
42.
Zurück zum Zitat Elflah M, Theofanous M, Dirar S, Yuan H (2019) Structural behaviour of stainless steel beam-to-tubular column joints. Eng Struct 184:158–175CrossRef Elflah M, Theofanous M, Dirar S, Yuan H (2019) Structural behaviour of stainless steel beam-to-tubular column joints. Eng Struct 184:158–175CrossRef
43.
Zurück zum Zitat JGJ, 82-2011, (2011) Technical Specification for High Strength Bolt Connections of Steel Structures, China Architecture and Building Press, Beijing JGJ, 82-2011, (2011) Technical Specification for High Strength Bolt Connections of Steel Structures, China Architecture and Building Press, Beijing
44.
Zurück zum Zitat Shi YP, Zhou YR (2004) Explain of Finite Element Analysis with Examples Using Abaqus. China Machine Press, Beijing Shi YP, Zhou YR (2004) Explain of Finite Element Analysis with Examples Using Abaqus. China Machine Press, Beijing
45.
Zurück zum Zitat Standardization Administration of China (SAC), GBT 20878 Stainless and heat-resisting steels- Designation and chemical composition, China Standard Press, Beijing, 2007. Standardization Administration of China (SAC), GBT 20878 Stainless and heat-resisting steels- Designation and chemical composition, China Standard Press, Beijing, 2007.
46.
Zurück zum Zitat S.A.o.C. (SAC), GB/T 706-2008, (2008) Hot rolled section steel, China Standard Press, Beijing S.A.o.C. (SAC), GB/T 706-2008, (2008) Hot rolled section steel, China Standard Press, Beijing
47.
Zurück zum Zitat Chen WF, Kishi N (1989) Semirigid steel beam-to-column connection: data base and modeling. J Struct Eng ASCE 115:105–119CrossRef Chen WF, Kishi N (1989) Semirigid steel beam-to-column connection: data base and modeling. J Struct Eng ASCE 115:105–119CrossRef
48.
Zurück zum Zitat Kong Z, Kim S-E (2017) Moment-rotation model of single-web angle connections. Int J Mech Sci 126(6):24–34CrossRef Kong Z, Kim S-E (2017) Moment-rotation model of single-web angle connections. Int J Mech Sci 126(6):24–34CrossRef
49.
Zurück zum Zitat Lee SS, Moon TS (2002) Moment–rotation model of semi-rigid connections with angles. Eng Struct 24:227–237CrossRef Lee SS, Moon TS (2002) Moment–rotation model of semi-rigid connections with angles. Eng Struct 24:227–237CrossRef
50.
Zurück zum Zitat Kishi N, Chen WF (1990) Moment-rotation relations of semirigid connections with angles. J Struct Eng 116(7):1813–1834CrossRef Kishi N, Chen WF (1990) Moment-rotation relations of semirigid connections with angles. J Struct Eng 116(7):1813–1834CrossRef
51.
Zurück zum Zitat Yang JG, Lee GY (2007) Analytical models for the initial rigidity and ultimate moment of a double angle connection. Eng Struct 29:542–551CrossRef Yang JG, Lee GY (2007) Analytical models for the initial rigidity and ultimate moment of a double angle connection. Eng Struct 29:542–551CrossRef
52.
Zurück zum Zitat Kong Z, Kim SE (2016) Numerical estimation of the initial stiffness and ultimate moment capacity of single-web angle connections. J Constr Steel Res 121:282–290CrossRef Kong Z, Kim SE (2016) Numerical estimation of the initial stiffness and ultimate moment capacity of single-web angle connections. J Constr Steel Res 121:282–290CrossRef
53.
Zurück zum Zitat Gong Y (2009) Design moment of shear connections at the ultimate limit state. J Constr Steel Res 65(10):1921–1930CrossRef Gong Y (2009) Design moment of shear connections at the ultimate limit state. J Constr Steel Res 65(10):1921–1930CrossRef
54.
Zurück zum Zitat Fan SG, Zheng JC, Sun WJ, Xia XF, Liu MJ (2017) Experimental investigation on mechanical properties of S30408 austenitic stainless steel at elevated temperatures. Eng Mech 34(004):167–176 Fan SG, Zheng JC, Sun WJ, Xia XF, Liu MJ (2017) Experimental investigation on mechanical properties of S30408 austenitic stainless steel at elevated temperatures. Eng Mech 34(004):167–176
55.
Zurück zum Zitat Li H (2017) Evaluation on the residual mechanical behavior of stainless steel space trusses after the fire. Tianjin University, Tianjin Li H (2017) Evaluation on the residual mechanical behavior of stainless steel space trusses after the fire. Tianjin University, Tianjin
56.
Zurück zum Zitat Ansi B (2005) AISC 360–05-Specification for Structural Steel Buildings. Illinois, Chicago Ansi B (2005) AISC 360–05-Specification for Structural Steel Buildings. Illinois, Chicago
57.
Zurück zum Zitat Guo H, Xiao F, Liu Y et al (2018) Experimental and numerical study on the mechanical behavior of Q460D high-strength steel bolted connections. J Constr Steel Res 151:108–121CrossRef Guo H, Xiao F, Liu Y et al (2018) Experimental and numerical study on the mechanical behavior of Q460D high-strength steel bolted connections. J Constr Steel Res 151:108–121CrossRef
58.
Zurück zum Zitat Huang Y, Wang R, Zou J et al (2010) Finite element analysis and experimental study on high strength bolted friction grip connections in steel bridges. J Constr Steel Res 66(6):803–815CrossRef Huang Y, Wang R, Zou J et al (2010) Finite element analysis and experimental study on high strength bolted friction grip connections in steel bridges. J Constr Steel Res 66(6):803–815CrossRef
59.
Zurück zum Zitat Qiang X, Shu Y, Jiang X (2022) Experimental and numerical study on high-strength steel flange-welded web-bolted connections under fire conditions. J Constr Steel Res 192:107255CrossRef Qiang X, Shu Y, Jiang X (2022) Experimental and numerical study on high-strength steel flange-welded web-bolted connections under fire conditions. J Constr Steel Res 192:107255CrossRef
Metadaten
Titel
Numerical Analysis for Behavior of Stainless-Steel Web Cleat Connections at Elevated Temperatures
verfasst von
Zhengyi Kong
Cuiqiang Shi
Bo Yang
George Vasdravellis
Seung-Eock Kim
Quang-Viet Vu
Publikationsdatum
31.12.2023
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 1/2024
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-023-01524-2

Weitere Artikel der Ausgabe 1/2024

Fire Technology 1/2024 Zur Ausgabe